Aufgabe 6: Synchronisation
Serial interface. More...
#include <machine/serial.h>
Public Types | |
enum | ComPort { COM1 = 0x3f8 , COM2 = 0x2f8 , COM3 = 0x3e8 , COM4 = 0x2e8 } |
COM-Port. More... | |
enum | BaudRate { BAUD_300 = 384 , BAUD_600 = 192 , BAUD_1200 = 96 , BAUD_2400 = 48 , BAUD_4800 = 24 , BAUD_9600 = 12 , BAUD_19200 = 6 , BAUD_38400 = 3 , BAUD_57600 = 2 , BAUD_115200 = 1 } |
Transmission speed. More... | |
enum | DataBits { DATA_5BIT = 0 , DATA_6BIT = 1 , DATA_7BIT = 2 , DATA_8BIT = 3 } |
Number of data bits per character. | |
enum | StopBits { STOP_1BIT = 0 , STOP_1_5BIT = 4 , STOP_2BIT = 4 } |
Number of stop bits per character. | |
enum | Parity { PARITY_NONE = 0 , PARITY_ODD = 8 , PARITY_EVEN = 24 , PARITY_MARK = 40 , PARITY_SPACE = 56 } |
parity bit | |
Public Member Functions | |
Serial (ComPort port=COM1, BaudRate baud_rate=BAUD_115200, DataBits data_bits=DATA_8BIT, StopBits stop_bits=STOP_1BIT, Parity parity=PARITY_NONE) | |
Constructor. More... | |
int | read (bool blocking=true) |
Read one byte from the serial interface. More... | |
int | write (char out, bool blocking=true) |
Write one byte to the serial interface. More... | |
bool | receiveInterrupt (bool enable) |
Activate or deactivate interrupts on data reception. More... | |
Protected Attributes | |
const ComPort | port |
Selected COM port. | |
Detailed Description
Serial interface.
This class provides a serial interface (COM1 - COM4) for communication with the outside world.
The first IBM PC used the external chip 8250 UART, whereas, in today's systems, this functionality is commonly integrated into the southbridge, but remained compatible.
- See also
- PC8250A Data Sheet (Registers on page 11)
- PC16550D Data Sheet (Successor, for optional FIFO buffer, page 16)
Member Enumeration Documentation
enum Serial::ComPort |
COM-Port.
The serial interface and its hardware addresses. Modern desktop PCs have, at most, a single, physical COM-port (COM1
)
enum Serial::BaudRate |
Transmission speed.
The unit Baud describes the transmission speed in number of symbols per seconds. 1 Baud therefore equals the transmission of 1 symbol per second. The possible Baud rates are whole-number dividers of the clock frequency of 115200 Hz..
Constructor & Destructor Documentation
|
explicit |
Constructor.
Creates a Serial object that encapsulates the used COM port, as well as the parameters used for the serial connection. Default values are 8N1
(8 bit, no parity bit, one stop bit) with 115200 Baud using COM1.
Member Function Documentation
int Serial::read | ( | bool | blocking = true | ) |
Read one byte from the serial interface.
- Parameters
-
blocking If set, read() blocks until one byte was read
- Returns
- Value read from serial interface (or
-1
if non-blocking and no data ready)
int Serial::write | ( | char | out, |
bool | blocking = true |
||
) |
Write one byte to the serial interface.
- Parameters
-
out Byte to be written blocking If set, write() blocks until the byte was written
- Returns
- Byte written (or
-1
if writing byte failed)
bool Serial::receiveInterrupt | ( | bool | enable | ) |
Activate or deactivate interrupts on data reception.
Calling this function reconfigures the respective register and flushes the receive buffer.
- Parameters
-
enable If true
, interrupts will be enabled, otherwise disabled.
- Returns
- Previous interrupt state.
The documentation for this class was generated from the following files:
- machine/serial.h
- machine/serial.cc